- 공동주택 현장 측정자료를 활용한 중량충격원의 바닥충격음 차단성능 비교
- ㆍ 저자명
- 윤창연,연준오,김명준,Yun. Chang-Yeon,Yeon. Jun-Oh,Kim. Myung-Jun
- ㆍ 간행물명
- 한국소음진동공학회논문집
- ㆍ 권/호정보
- 2014년|24권 8호|pp.651-658 (8 pages)
- ㆍ 발행정보
- 한국소음진동공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
Notification 2013-611 of MOLIT has come into effect. It relates primarily to new standard impact source. In this study, an in-depth experimental analysis of the difference between a bang machine and an impact ball was performed via field testing of shear wall and flat plate structure at 51 sites. This paper focuses on the difference in single number quantities between a bang machine and an impact ball. At wall thicknesses of 180 and 210 mm in shear wall structure, the single number quantities exhibited differences of 3.1 and 4.5 dB, respectively, and at thicknesses exceeding 250 mm in flat plate structure, the difference was constant at 4.6 dB. With regard to flat plate structures, the single-index difference increased up to 11 dB as the thickness of the floor slab increased. In general, the highest level of contribution for the bang machine was 63 Hz, irrespective of thickness determining bandwidth. The highest level for the impact ball were 63 Hz and 125 Hz. In future research, when reviewing additional field performance measurement data, it will be necessary to consider a detailed examination instead of the current method of uniformly adding 3 dB for all thicknesses and types of structures.