Qualification and application of a liquid chromatography-tandem mass spectrometric method for the determination of human $A{eta}1$-40 and $A{eta}1$-42 peptides in transgenic mouse plasma using
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Qualification and application of a liquid chromatography-tandem mass spectrometric method for the determination of human $A{eta}1$-40 and $A{eta}1$-42 peptides in transgenic mouse plasma using
  • Qualification and application of a liquid chromatography-tandem mass spectrometric method for the determination of human $A{eta}1$-40 and $A{eta}1$-42 peptides in transgenic mouse plasma using
저자명
Shin. Young G.,Lee. Hamm,Murakami. Stanley,Buirst. Kenji,Buonarati. Michael H.,Cox. April,Regal. Kelly,Hunt. Kevin W.,Scearce-Le
간행물명
Archives of pharmacal research : a publication of the Pharmaceutical Society of Korea
권/호정보
2014년|37권 5호|pp.636-644 (9 pages)
발행정보
대한약학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

A liquid chromatographic-tandem mass spectrometric (LC-MS/MS) method was developed and applied for the determination of human $A{eta}1$-40 and $A{eta}1$-42 peptides in transgenic mouse plasma to support preclinical pharmacodynamics studies. The method consisted of micro-elution solid phase extraction for sample preparation and LC-MS/MS analysis in the negative ion mode using electrospray ionization for analysis. $^{15}N_{53}-A{eta}1$-40 and $^{15}N_{55}-A{eta}1$-42 peptides were used as internal standards. A quadratic regression (weighted 1/concentrations), with an equation $y=ax^2+bx+c$, was used to fit calibration curves over the concentration range of 0.500-100 ng/mL for both $A{eta}1$-40 and $A{eta}1$-42 peptides. For quality control samples at 6.00, 40.0 and 80.0 ng/mL from the qualification experiment, the within-run accuracy ranged from -2.69 to 0.583 % with precision values ${geq}8.23%$ for $A{eta}1$-40. Within-run accuracy ranged from -4.83 to 10.1 % with precision values ${geq}8.87%$ for $A{eta}1$-42. Samples from a pharmacodynamics study using Tg2576 transgenic mice were analyzed by this qualified LC-MS/MS method and concentrations were compared to those generated by ELISA. The two methods were shown to be comparable for $A{eta}1$-40 quantification of samples from the Tg2576 amyloid precursor protein transgenic mouse model, but varied slightly for $A{eta}1$-42.