기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
Viscosity and Wettability of Hyaluronic Acid according to Antimicrobial Supplementation, Ionic Strength, and pH
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Viscosity and Wettability of Hyaluronic Acid according to Antimicrobial Supplementation, Ionic Strength, and pH
  • Viscosity and Wettability of Hyaluronic Acid according to Antimicrobial Supplementation, Ionic Strength, and pH
저자명
Kho. Hong-Seop,Chang. Ji-Youn,Kim. Yoon-Young,Park. Moon-Soo
간행물명
Journal of Oral Medicine and Pain
권/호정보
2014년|39권 3호|pp.90-95 (6 pages)
발행정보
대한안면통증구강내과학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Purpose: To investigate viscosity and wettability of hyaluronic acid (HA) solutions according to supplementation of lysozyme and/or peroxidase, and different ionic strength and pH conditions. Methods: Solutions containing HA were prepared using distilled deionized water (DDW) and simulated salivary buffer (SSB) in different conditions. Different concentrations of hen egg-white lysozyme and bovine lactoperoxidase was added into HA solutions. HA solutions with antimicrobials in different ionic strength and pH conditions were prepared. Viscosity was measured using cone-and-plate digital viscometer at six different shear rates and wettability on acrylic resin and Co-Cr alloy was determined by contact angle. Results: The viscosity values of HA dissolved in DDW were decreased in order of HA, HA containing lysozyme, HA containing peroxidase, and HA containing lysozyme and peroxidase. The viscosity values for HA in DDW were decreased as the concentration of lysozyme and/or peroxidase increased. However, the viscosity values for HA in SSB showed no significant changes according to the concentration of lysozyme and/or peroxidase. The viscosity values of HA solutions were inversely proportional to ionic strength and pH. The contact angle of HA solutions showed no significant differences according to tested surface materials, addition of lysozyme and/or peroxidase, and different ionic strength and pH conditions. Contact angles on acrylic resin by HA solutions in all tested conditions were much higher than those by human saliva. Conclusions: The rheological properties of HA supplemented with lysozyme and/or peroxidase in different ionic strength and pH conditions were objectively confirmed, indicating the possibility of HA with lysozyme and/or peroxidase as main components in the development of effective saliva substitutes.