기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
國産스테인레스鋼線系 矯正用線材의 開發과 物理的 性質에 關한 硏究
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 國産스테인레스鋼線系 矯正用線材의 開發과 物理的 性質에 關한 硏究
  • A STUDY ON DEVELOPMENT AND PHYSICAL PROPERTIES OF STAINLESS STEEL ORTHODONTIC WIRES MADE IN KOREA
저자명
성재현(Jae-Hyun Sung),권오원(Oh-Won Kwon),경희문(Hee-Moon Kyung),이기대(Kee-Dae Lee)
간행물명
The Korean Journal of OrthodonticsKCI,SCIE,SCOPUS
권/호정보
1989년|19권 2호|pp.7-24 (18 pages)
발행정보
대한치과교정학회|한국
파일정보
정기간행물|KOR|
PDF텍스트(1.28MB)
주제분야
의약학
서지반출

영문초록

The physical properties of seven sizes of control groups and experimental group in stainless steel orthodontic wires were studied in tension, hardness, bending, torsion and observation of microstructure. The wires (0.40-0.90mm dia.) of round type were tested in the as-received condition. The wires of control groups were TRU-CHROME and REMANlUM, and experimental group was SK wire which was developed by ourselves and made in Korea. The results were as follows; 1. The chemical compositions of control groups and experimental group were austenite stainless steel wires of SOS 304. 2. Higher values of tensile and yield strength in tension were control group I, experimental group, control group II. Maximum tensile and yield strength of experimental group were 203.63 ± 1.41kgjmm² in 0.70mm diameter and 148.96 ± 4.88kg/mm² in 0.60mm diameter, and maximum elongation was 5.20 ± 0.57% in 0.45mm diameter. 3. Hardness values of experimental group were similar to control groups. Maximum hardness values were 596.2 ± 13.66Hv in 0.45mm diameter wire of control group I, 5 90.5 ± 20.08Hv in 0.50mm diameter wire of control group II, and 563.6 ± 5.35Hv in 0.70mm diameter wire of experimental group. 4. Torsion properties of experimental group were similar to control group I and more than control group II. Maximum torsion cycles were 31.8 ± 2.48 in 0.45mm diameter of control group I, 17.4 ± 4.84 in 0.60mm diameter of control group II, and 24.6 ± 3.04 in 0.45mm diameter of experimental group. 5. Maximum bending cycles of experimental group were smaller than control groups. Maximum bending cycles were 9.00 ± 0.00 in 0.50mm diameter wire of control group I, 10.0 ± 0.82 in 0.40mm diameter wire of control group II, and 8.0 ± 1.26 in 0.50mm diameter wire of experimental group. 6. Microstructures of experimental and control groups co-existed with martensited austenite structure and elongated austenite structure. 7. The direction of wire fracture was propagated parallel to torsion direction typically and there was no probability showing wire fracture at inclusions and surface scratches. 8. The type of wire fracture was brittle fracture at initiation site and ductile fracture at core.