기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
Accuracy of three-dimensional cephalograms generated using a biplanar imaging system
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Accuracy of three-dimensional cephalograms generated using a biplanar imaging system
저자명
Ha-Yeon Park,Jae-Seo Lee,Jin-Hyoung Cho,Hyeon-Shik Hwang,Kyung-Min Lee
간행물명
The Korean Journal of OrthodonticsKCI,SCIE,SCOPUS
권/호정보
2018년|48권 5호|pp.292-303 (12 pages)
발행정보
대한치과교정학회|한국
파일정보
정기간행물|ENG|
PDF텍스트(4.3MB)
주제분야
의약학
서지반출

영문초록

Objective: Biplanar imaging systems allow for simultaneous acquisition of lateral and frontal cephalograms. The purpose of this study was to compare measurements recorded on three-dimensional (3D) cephalograms constructed from two-dimensional conventional radiographs and biplanar radiographs generated using a new biplanar imaging system with those recorded on conebeam computed tomography (CBCT)-generated cephalograms in order to evaluate the accuracy of the 3D cephalograms generated using the biplanar imaging system. Methods: Three sets of lateral and frontal radiographs of 15 human dry skulls with prominent facial asymmetry were obtained using conventional radiography, the biplanar imaging system, and CBCT. To minimize errors in the construction of 3D cephalograms, fiducial markers were attached to anatomical landmarks prior to the acquisition of radiographs. Using the 3D CephTM program, 3D cephalograms were constructed from the images obtained using the biplanar imaging system (3D cephbiplanar), conventional radiography (3D cephconv), and CBCT (3D cephcbct). A total of 34 measurements were obtained compared among the three image sets using paired t-tests and Bland–Altman plotting. Results: There were no statistically significant differences between the 3D cephbiplanar and 3D cephcbct measurements. In addition, with the exception of one measurement, there were no significant differences between the 3D cephcbct and 3D cephconv measurements. However, the values obtained from 3D cephconv showed larger deviations than those obtained from 3D cephbiplanar. Conclusions: The results of this study suggest that the new biplanar imaging system enables the construction of accurate 3D cephalograms and could be a useful alternative to conventional radiography.

영문초록

Objective: Biplanar imaging systems allow for simultaneous acquisition of lateral and frontal cephalograms. The purpose of this study was to compare measurements recorded on three-dimensional (3D) cephalograms constructed from two-dimensional conventional radiographs and biplanar radiographs generated using a new biplanar imaging system with those recorded on conebeam computed tomography (CBCT)-generated cephalograms in order to evaluate the accuracy of the 3D cephalograms generated using the biplanar imaging system. Methods: Three sets of lateral and frontal radiographs of 15 human dry skulls with prominent facial asymmetry were obtained using conventional radiography, the biplanar imaging system, and CBCT. To minimize errors in the construction of 3D cephalograms, fiducial markers were attached to anatomical landmarks prior to the acquisition of radiographs. Using the 3D CephTM program, 3D cephalograms were constructed from the images obtained using the biplanar imaging system (3D cephbiplanar), conventional radiography (3D cephconv), and CBCT (3D cephcbct). A total of 34 measurements were obtained compared among the three image sets using paired t-tests and Bland–Altman plotting. Results: There were no statistically significant differences between the 3D cephbiplanar and 3D cephcbct measurements. In addition, with the exception of one measurement, there were no significant differences between the 3D cephcbct and 3D cephconv measurements. However, the values obtained from 3D cephconv showed larger deviations than those obtained from 3D cephbiplanar. Conclusions: The results of this study suggest that the new biplanar imaging system enables the construction of accurate 3D cephalograms and could be a useful alternative to conventional radiography.

목차

INTRODUCTION  MATERIALS AND METHODS  RESULTS  DISCUSSION  CONCLUSION  CONFLICTS OF INTEREST  ACKNOWLEDGEMENTS