기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
Receiver operating characteristic curve analysis of the timed up and go test as a predictive tool for fall risk in persons with stroke
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Receiver operating characteristic curve analysis of the timed up and go test as a predictive tool for fall risk in persons with stroke
  • Receiver operating characteristic curve analysis of the timed up and go test as a predictive tool for fall risk in persons with stroke: a retrospective study
저자명
Seung-yeop Lim,Byung-jun Lee,Wan-hee Lee
간행물명
Physical Therapy Rehabilitation ScienceKCI
권/호정보
2018년|7권 2호(통권17호)|pp.54-60 (7 pages)
발행정보
물리치료재활과학회|한국
파일정보
정기간행물|ENG|
PDF텍스트(11.23MB)
주제분야
의약학
서지반출

영문초록

Objective: Persons with chronic stroke fall more often than healthy elderly individuals. The Timed Up and Go test (TUG) is used as a fall prediction tool, but only provides a result for the total measurement time. This study aimed to determine the optimal cut-off values for each of the 6 components of the TUG. Design: Retrospective study. Methods: Thirty persons with chronic stroke participated in the study. TUG evaluation was performed using a wearable miniaturized inertial sensor. Sensitivity, specificity, and predictive values were calculated using the Receiver Operating Characteristic (ROC) curve analysis for the measured values in each section. Optimal values for fall risk classification were determined. Logistic regression analysis was used to investigate the risk of future falls based on TUG. Results: The cut-off values of the 6 sections of the TUG were determined, as follows: sit-to-stand >2.00 seconds (p<0.05), forward gait >4.68 seconds (p<0.05), mid-turn >3.82 seconds (p<0.05), return gait >4.81 seconds (p<0.05), end-turn >2.95 seconds (p<0.05), and stand-to-sit >2.13 seconds (p<0.05). The risk of falling increased by 2.278 times when the mid-turn value was >3.82 seconds (p<0.05). Conclusions: The risk of falls increased by 2.28 times when the value of the mid-turn interval exceeded 3.82 seconds. Therefore, when interpreting TUG results, the predictive accuracy for falls will be higher when the measurement time for each section is analyzed, together with the total time for TUG.

영문초록

Objective: Persons with chronic stroke fall more often than healthy elderly individuals. The Timed Up and Go test (TUG) is used as a fall prediction tool, but only provides a result for the total measurement time. This study aimed to determine the optimal cut-off values for each of the 6 components of the TUG. Design: Retrospective study. Methods: Thirty persons with chronic stroke participated in the study. TUG evaluation was performed using a wearable miniaturized inertial sensor. Sensitivity, specificity, and predictive values were calculated using the Receiver Operating Characteristic (ROC) curve analysis for the measured values in each section. Optimal values for fall risk classification were determined. Logistic regression analysis was used to investigate the risk of future falls based on TUG. Results: The cut-off values of the 6 sections of the TUG were determined, as follows: sit-to-stand >2.00 seconds (p<0.05), forward gait >4.68 seconds (p<0.05), mid-turn >3.82 seconds (p<0.05), return gait >4.81 seconds (p<0.05), end-turn >2.95 seconds (p<0.05), and stand-to-sit >2.13 seconds (p<0.05). The risk of falling increased by 2.278 times when the mid-turn value was >3.82 seconds (p<0.05). Conclusions: The risk of falls increased by 2.28 times when the value of the mid-turn interval exceeded 3.82 seconds. Therefore, when interpreting TUG results, the predictive accuracy for falls will be higher when the measurement time for each section is analyzed, together with the total time for TUG.

목차

Introduction Methods Results Discussion

구매하기 (3,000)