This study was performed to evaluate the accuracy of orthopantomogram by measuring the actual and radiographic tooth length and by analyzing the vertical magnification rate. For this study, total 90 teeth of the maxilla and mandible teeth and a dry skull were used. This experiment was attached with metal balls of 1±0.02㎜ at the root and the crown cusp tips of central, 2nd premolar, 1st molar of the maxilla and mandible and the teeth were embedded in dry skull, and then orthopantomogram was taken. The obtained results were as follows: 1. The average of tooth length in orthopantomogram was longer than that of actual tooth length. 2. The average of vertical magnification rate in the orthopantomogram to actual tooth length was 17-26%. 3. Vertical magnification rate of the maxilla teeth was 18-26% and that of mandibular teeth was 17-23%, and the magnification of maxillary teeth was larger than that of mandible teeth(P<0.0l). 4. Vertical magnification rate of posterior area was 22-26% and that of anterior area was 17-18%, and the magnification of anterior area was less than that of posterior area(P<0.01).