- 2단 선회류 약화기가 원심력집진기의 집진효율에 미치는 영향
- ㆍ 저자명
- 강순국,유경선
- ㆍ 간행물명
- 한국대기환경학회지
- ㆍ 권/호정보
- 2000년|16권 6호|pp.633-640 (8 pages)
- ㆍ 발행정보
- 한국대기환경학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
The effects of structure modification of the vortex finder on the collection efficiency and pressure drop have been investigated. The pressure drop in a cyclone having the two stage vortex finder is higher than that in a conventional cyclone and increases proportionally with the increase of square of gas inlet velocity in both cases. The pressure drop of both conventional cyclone of friction resistance at the boundary layer. The collection efficiency of fine dust has been enhanced by addition of vortex finder in a conventional cyclone and gas inlet velocity showing maximum dust removal efficiency increase to 17 m/s(1.7 times of saltation velocity). Optimum size of two stage vortex finder has been induced to 13 cm I.D$ imes$2.6cm Length from the results of overall dust collection efficiency. Previous models were tested for the simulation of collection efficiency of cyclone having two stage vortex finder and the Dietz model predict the similar value with experimental results of the present study.