Practical devices for measuring personal exposure to nitrogen dioxide(NO$_2$) have been made for epidemiological studies of the health effects of air pollution Standard methods for NO$_2$ measurement such as the chemiluminescent method and Saltzman method are not suitable for personal exposure because they are heavy, large and complicated to operate. In this study, a passive monitor was tested for the measurements of indoor and outdoor NO$_2$ level. Through a comparative analysis of data sets obtained by on-site chemiluminescence system, we assessed the accuracy and precision of NO$_2$ passive monitors. We also examined the possibility of passive monitor in the study of indoor, outdoor and personal NO$_2$ exposure. The accuracy and precision of NO$_2$ passive monitor were analyzed assuming measurements of on-site chemiluminescence system is reference value and using duplicated measure- ments, respectively. From these analysis the NO$_2$ passive monitor was useful for measuring indoor, outdoor and personal exposure. And NO$_2$ level from on-site chemiluminescence systems could not properly represent the personal NO$_2$ exposure as well as indoor and outdoor level of ones house. Personal exposures were correlated more strongly with indoor NO$_2$ concentrations than with outdoor NO$_2$ concentrations. Since activity pattern of each person is different, it was considered that personal daily behavior and life-style might prevent the air pollutant exposure