- 서울지역 학교 교실의 실내환경 조사연구
- ㆍ 저자명
- 최한영
- ㆍ 간행물명
- 大韓衛生學會誌
- ㆍ 권/호정보
- 2003년|18권 2호|pp.67-74 (8 pages)
- ㆍ 발행정보
- 대한위생학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
In 15 schools where were chosen each location (East, West, South, North, Central) of Seoul area, 9 items were measured such as thermo circumstance(temperature, relative humidity, air current, intensity of illumination) particulate matter, carbon monoxide, sulfur dioxide, and nitrogen dioxide being based on the school indoor environment standard. It was showed that indoor temperature, relative humidity and air movement were suitable in comparison with school indoor environment standard. Intensity of illumination was suitable in comparison with all schools, only exception 2 schools. In all investigated schools were adequate for carbon monoxide, sulfur dioxide and nitrogen dioxide, in which each indoor environment standard (10ppw, 0.25ppm/hr, 0.15ppm/hr), but in 5 schools the carbon dioxide were exceeded for standard limit 1,000ppm of Korea. Indoor concentration of dust(PM-10) induced from respiration dust the standard of Korea ($150{mu}g/m^3$) at all schools.