- 소형 판막 펌프를 이용한 기질용액 채취 및 여과 자동화 장치의 성능검증
- ㆍ 저자명
- 송대빈,정효석,이승규,정대홍,박성우,Song. D.B.,Jung. H.S.,Lee. S.K.,Jung. D.H.,Park. S.W.
- ㆍ 간행물명
- 바이오시스템공학
- ㆍ 권/호정보
- 2007년|32권 4호|pp.263-268 (6 pages)
- ㆍ 발행정보
- 한국농업기계학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
An auto sampling and filtering unit was developed for monitoring automation of a fermentation process and its performance was evaluated. The automatic sampling and filtering unit was constructed with a glass filter, a diaphragm suction pump, and a flow direction change valve. To evaluate operating stability, delivery volumes of the suction pump were measured according to the experimental conditions of cellulose powder, pore size of the glass filter and suction head of the pump. The developed unit could deliver the sample solution under any experimental conditions except the filter pore size of $16{mu}m$ and the suction head of 20cm. In case of the suction head of 30cm, the pump could not deliver the sample solution at all. Concentrations of the sample solutions were converged on those of the standard glucose solution after 8 minutes from the initial sampling time. The relative error of concentration between the sample and the standard solution showed 3.8, 4.8, 7.0% for the 1, 3, 5% contents of cellulose powder, respectively.